High oil pressure switch
High oil temperature switch
Temperature compensated pressure switch
Temperature compensated thermal time delay switch

Übersetzung für "temperature compensated pressure switch " (Englisch → Französisch) :

TERMINOLOGIE
temperature compensated pressure switch

mano-contact à compensation thermique


high oil pressure switch | high oil temperature switch

manocontact de haute température d'huile | mano-contact de haute température d'huile


temperature compensated thermal time delay switch

interrupteur à retard thermique compensé en température
IN-CONTEXT TRANSLATIONS
(b) to limit the rate of change of the temperature or pressure of the liquid to be measured by the meter when the meter is equipped with an automatic compensator,

b) de limiter la vitesse à laquelle change la température ou la pression du liquide à mesurer par un compteur muni d’un compensateur automatique,


(b) to limit the rate of change of the temperature or pressure of the liquid to be measured by the meter when the meter is equipped with an automatic compensator,

b) de limiter la vitesse à laquelle change la température ou la pression du liquide à mesurer par un compteur muni d’un compensateur automatique,


’safety accessories’ means devices designed to protect pressure equipment against the allowable limits being exceeded, including devices for direct pressure limitation, such as safety valves, bursting disc safety devices, buckling rods, controlled safety pressure relief systems (CSPRS), and limiting devices, which either activate the means for correction or provide for shutdown or shutdown and lockout, such as pressure switches or temperature switches or fluid level switches and safety related ...[+++]

«accessoires de sécurité», des dispositifs conçus pour protéger des équipements sous pression contre le dépassement des limites admissibles, y compris des dispositifs pour la limitation directe de la pression, tels que les soupapes de sûreté, les dispositifs à disques de rupture, les tiges de flambage, les dispositifs de sécurité asservis (CSPRS) et des dispositifs de limitation qui mettent en œuvre des moyens d'intervention ou entraînent la coupure ou la coupure et le verrouillage, tels que les commutateurs actionnés par la pression, la température ou le niv ...[+++]


Dangerous overloading of equipment must be prevented at the design stage by means of integrated measurement, regulation and control devices, such as over-current cut-off switches, temperature limiters, differential pressure switches, flowmeters, time-lag relays, overspeed monitors and/or similar types of monitoring devices.

Il faut éviter que les appareils ne soient surchargés de manière dangereuse au moyen de dispositifs intégrés de mesurage, de commande et de réglage et ceci dès leur conception, notamment au moyen de limitateurs de surintensité, de limitateurs de température, d'interrupteurs de pression différentielle, de débitmètres, de relais temporisés, de compte-tours et/ou de dispositifs de surveillance du même genre.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
‘safety accessories’ means devices designed to protect pressure equipment against the allowable limits being exceeded, including devices for direct pressure limitation, such as safety valves, bursting disc safety devices, buckling rods, controlled safety pressure relief systems (CSPRS), and limiting devices, which either activate the means for correction or provide for shutdown or shutdown and lockout, such as pressure switches or temperature switches or fluid level switches and safety related ...[+++]

4) «accessoires de sécurité»: des dispositifs conçus pour protéger des équipements sous pression contre le dépassement des limites admissibles, y compris des dispositifs pour la limitation directe de la pression, tels que les soupapes de sûreté, les dispositifs à disques de rupture, les tiges de flambage, les dispositifs de sécurité asservis (CSPRS) et des dispositifs de limitation qui mettent en œuvre des moyens d’intervention ou entraînent la coupure ou la coupure et le verrouillage, tels que les commutateurs actionnés par la pression, la température ou le niv ...[+++]


(2) Subsection (1) does not apply to a register that is altered to operate with automatic temperature, pressure or density compensation.

(2) Le paragraphe (1) ne s’applique pas à l’enregistreur qui est modifié de façon à fonctionner avec compensation automatique de température, de pression ou de masse volumique.


6.1 (1) Subject to subsection (2), a meter register approved under section 3 of the Act that has no means, or has means that are not in use, of automatic temperature, pressure or density compensation is exempt from paragraph 8(b), subsection 15(1) and paragraph 26(1)(c) of the Act if it is installed as a replacement register on a volumetric liquid meter that has previously been examined and certified for the purposes of paragraph 8(b) of the Act.

6.1 (1) Sous réserve du paragraphe (2), l’enregistreur de compteur approuvé en vertu de l’article 3 de la Loi qui ne comporte pas de dispositif de compensation automatique de température, de pression ou de masse volumique, ou qui comporte un tel dispositif, mais qui ne sert pas, est soustrait à l’application de l’alinéa 8b), du paragraphe 15(1) et de l’alinéa 26(1)c) de la Loi s’il est installé comme enregistreur de rechange sur un compteur volumétrique de liquide qui a préalablement été examiné et certifié pour l’application de l’alinéa 8b) de la Loi.


2.2.1. Determination of the Diluted Exhaust Gas Flow PDP-CVS system The calculation of the mass flow over the cycle, if the temperature of the diluted exhaust is kept within ± 6 K over the cycle by using a heat exchanger, is as follows: M TOTW = 1,293 x V0 x NP x (pB - p1 ) x273 / (101,3 x T) where M TOTW = mass of the diluted exhaust gas on wet basis over the cycle V0 = volume of gas pumped per revolution under test conditions (m³/rev) NP = total revolutions of pump per test pB = atmospheric pressure in the te ...[+++]

2.2.1. Détermination du débit de gaz d'échappement dilués Système PDP-CVS Le débit massique durant le cycle est calculé comme suit si la température des gaz d'échappement dilués est maintenue dans une limite de ± 6 K durant tout le cycle à l'aide d'un échangeur de chaleur: M TOTW = 1,293 x V0 x NP x (pB - p1 ) x 273 / (101,3 x T) où: MTOTW = masse de gaz d'échappement dilués en conditions humides durant le cycle (en kg) V0 = volume de gaz pompé par tour dans les conditions d'essai (en m³/tr) NP = nombre total de tours de la pompe par essai PB = pression atmosphér ...[+++]


In this case, the instantaneous mass of the diluted exhaust gas shall be calculated as follows: M TOTW ,i = 1,293 x V0 x NP,i x (pB - p1 ) x 273 / (101,3 x T) where NP,i = total revolutions of pump per time interval CFV-CVS system The calculation of the mass flow over the cycle, if the temperature of the diluted exhaust gas is kept within ± 11K over the cycle by using a heat exchanger, is as follows: M TOTW = 1,293 x t x Kv x pA / T where M TOTW = mass of the diluted exhaust gas on wet basis over the cycle t = cycle time (s) KV = calibration coefficient of the critical flow v ...[+++]

Dans ce cas, la masse instantanée de gaz d'échappement dilués est calculée comme suit: M TOTW ,i = 1,293 x V0 x NP,i x (pB - p1 ) x 273 / (101,3 x T) où: NP,i = nombre total de tours de la pompe par intervalle de temps Système CFV-CVS Le débit massique durant le cycle est calculé comme suit si la température des gaz d'échappement dilués est maintenue dans une limite de ± 11 K durant tout le cycle à l'aide d'un échangeur de chaleur: M TOTW = 1,293 x t x Kv x pA / T où: MTOTW = masse de gaz d'échappement dilués en conditions humides dur ...[+++]


A0 = collection of constants and units conversions d = diameter of the SSV throat (m) Cd = discharge coefficient of the SSV PA = absolute pressure at venturi inlet (kPa) T = temperature at the venturi inlet (K) If a system with flow compensation is used (i.e. without heat exchanger), the instantaneous mass emissions shall be calculated and integrated over the cycle.

A0 = série de constantes et de conversions d'unités d = diamètre du col du SSV (en m) Cd = coefficient de décharge du SSV PA = pression absolue à l'entrée du venturi (en kPa) T = température à l'entrée du venturi (en K) Si un système à compensation de débit est utilisé (c'est-à-dire sans échangeur de chaleur), les émissions massiques instantanées doivent être déterminées et intégrées sur la durée du cycle.