Calculation of the Mass Flow The particulate mass MPT (g/test) shall be calculated as follows: PT where: Mf = particulate mass sampled over the cycle (mg) MTOTW = total mass of diluted exhaust gas over the cycle as determined in section 2.2.1 (kg) MSAM = mass of diluted exhaust
gas taken from the dilution tunnel for collecting particulates (kg) and, Mf = Mf,p + Mf,b , if weighed separately (mg) Mf,p = particulate mass collected on the primary filter (mg) Mf,b = particulate mass collected on the back-up filter (mg) I
f a double dilution system is used, the mass o ...[+++]f the secondary dilution air shall be subtracted from the total mass of the double diluted exhaust gas sampled through the particulate filters.Berechnung des Massendurchsatzes Die Partikelmasse MPT (g/Prüfung) berechnet sich wie folgt: PT Dabei ist: Mf = über den Zyklus abgeschiedene Partikelprobenahmemasse (mg) M TOTW = Gesamtmasse des verdünnten Abgases über den gesamten Zyklus gemäß Abschnitt 2.2.1 bestimmt (kg) M SAM = Masse des aus
dem Verdünnungstunnel zum Abscheiden von Partikeln entnommenen verdünnten Abgases (kg) und Mf = Mf,p + Mf,b , sofern getrennt gewogen (mg) Mf,p = am Hauptfilter abgeschiedene Partikelmasse (mg) Mf,b = am Nachfilter abgeschiedene Partikelmasse (mg) Bei Verwendung eines Doppelverdünnungssystems ist die Masse der Sekundärverdünnungsluft von der Ges
...[+++]amtmasse des zweifach verdünnten Abgases, das zur Probenahme durch die Partikelfiltern geleitet wurde, abzuziehen.